Product Code: PSEL-240
MPN #: MDS-350AD701
Losing data because your system powers down at the worst moment is frustrating. The Delta MDS-350AD701 350W, 12V Medical ATX 1U Power Supply delivers reliable 350 W of steady 12 V power, keeping computers, workstations and industrial controllers running smoothly without flicker or unexpected drops.
Many buyers worry about compatibility and safety when selecting a power supply for medical or industrial use. They often fear voltage spikes, insufficient output or lack of certifications. This unit removes those doubts with universal 90-264 Vac input, built-in active PFC and full IEC 60601-1 and IEC 62368-1 approvals, ensuring safe operation in demanding environments.
Ideal for medical equipment requiring type BF patient access, industrial controllers, and high-reliability workstations where uninterrupted 12 V power is critical.
| Input Ratings / Characteristics | |
| Nominal Input Voltage | 100–240 Vac |
| Input Voltage Range | 90–264 Vac |
| Nominal Input Frequency | 50–60 Hz |
| Input Frequency Range | 47–63 Hz |
| Input Current (max) | 6 A |
| Input Surge Voltage (max) | 300 Vac for 100 ms |
| Full load Efficiency (typ.) | 82% @ 115 Vac / 60 Hz 85% @ 230 Vac / 50 Hz |
| Inrush Current (max) | No damage, cold start |
| Leakage Current (max) | 0.1 mA @ NC0.3 mA @ SFC |
| Output-PE (protective earth) Leakage current for BF application (max) | 0.1 mA @ NC, 0.5 mA @ SFC |
| Power Factor (min) | 0.90 @ 115 V / 50 Hz, 230 V / 50 Hz, full load |
| Output Ratings / Characteristics | |
| Nominal Output Voltage (V rated) | +12 V1, +12 V2, +5 V, +3.3 V, +5 Vsb, -5 V, -12 V |
| Output Power | 350W |
| Line Regulation (max) | ±0.5% |
| Start-up Time (max) (Remote On_Off @ TTL Low, then AC applied) | 1000 ms @ 115 Vac |
| Hold-up Time (min) | 17 ms @ 115 Vac / 60 Hz |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ±10% @ 50–100% load |
| Rise Time (max) | 20 ms |
| Remote On_Off/INHIBIT | TTL Active Low: Output Enable TTL Active High: Output Disable |
| Mechanical | |
| Case Chassis | SECC (Steel, Electrogalvanized, Cold Rolled, Coil) |
| Case Cover | SECC (Steel, Electrogalvanized, Cold Rolled, Coil) |
| Dimensions (L × W × H) | 194 × 100 × 40.5 mm (7.64 × 3.94 × 1.59 inch) |
| Unit Weight (typ.) | 1.2 kg (2.6 lb) |
| Cooling System | Forced Cooling |
| Environment | |
| Surrounding Air Temperature | Operating: 0 °C to +50 °C Storage: -40 °C to +85 °C |
| Operating Humidity | 5–95% RH (Non-Condensing) |
| Operating Altitude | 5,000 meters (16,400 feet) |
| Shock Test (Non-Operating) | 50 G, 11 ms, 3 shocks for each direction |
| Vibration (Operating) | 5–500 Hz, 2 Grms, 15 minutes for each of three axes |
| Protections | |
| Overvoltage | For +3.3V output, Maximum voltage < 4.8V For +5V output, Maximum voltage < 7V For +12V1 & +12V2 outputs, Maximum voltage < 16V Protection Method: Latch Mode For +5Vsb output, Maximum voltage < 10V Protection Method: Latch Mode |
| Overload / Overcurrent | For +3.3V output, Maximum current < 25A For +5V output, Maximum current < 25A For +12V1/+12V2 output, Maximum current < 25A Protection Method: Latch Mode For +5Vsb output, Maximum current < 5A Protection Method: Auto-recovery Mode |
| Over Temperature | Protection Method: Latch Mode |
| Short Circuit | +3.3V, +5V, +12V1 and +12V2, Protection Method: Latch Mode+5Vsb Protection Method: Auto-recovery |
| Reliability | |
| MTBF | 500 K hrs based on Telecordia SR-332 |
| Expected Cap Life Time | 26,280 hrs |
| Safety | |
| Electrical Safety | IEC60950-1 (Ed.2,2005) & IEC 62368-1 CB report |
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015 |
| Medical Safety | IEC 60601-1 EN60601-1 CAN/CSA-C22.2 No. 60601-1 ANSI/AAMI ES60601-1 |
| Galvanic Isolation | Input to Output (2XMOPP): 4000 Vac Input to/Ground (1XMOPP): 1500 Vac Output to/Ground (1XMOPP): 1500 Vac (Type BF application rated) |
| UKCA | In conformance with Electrical Equipment (Safety) Regulations 2016 Electromagnetic Compatibility Regulations 2016 Medical Devices Regulations 2002 (UK MDR 2002) |
| EMC | |
| Emission | EN/BS EN 55011 & Compliant with EN/BS EN 55032, FCC Title 47: Class B |
| Harmonic Current Emissions | IEC 61000-3-2: Meet Class D limit |
| Voltage Fluctuation and Flicker | IEC 61000-3-3 |
| ESD Immunity | IEC 61000-4-2 |
| Radiated Immunity | IEC 61000-4-3 IEC 60601-1-2 |
| EFT | IEC 61000-4-4 |
| Surge | IEC 61000-4-5 |
| Conducted Immunity | IEC 61000-4-6 |
| Magnetic Field | IEC 61000-4-8 |
| Voltage Dips | IEC 60601-1-2 IEC 61000-4-11 |
Be the first to write a review
We are retiring PICOPC Products MNHO-073, MNHO-048 and MNHO-043 and they have reached EOL (End Of Life) as we are introducing new products with better technology. We would recommend you to look into MNHO-095. For Untangle, pfSense, OPNsense, Windows 11, Proxmox VE etc. we recommend MNHO-095 whereas for Sophos, Kerio Control and Endian, we would recommend MNHO-069. (A complete list of supported OS can be found in each product's listing)